Home › Projects › PRJNA1354999
PRJNA1354999 SRP638065 DNA

Tissue mNGS for suspected infections, China

Archive title: Diagnostic utility of metagenomic next-generation sequencing for tissue in patients with suspected infectious diseases.

46 tissue specimens (mostly unspecified sites, 1 blood/tissue) from 64 patients with suspected infectious diseases in China, collected in 2022, sequenced by shotgun metagenomics (DNA) to evaluate pathogen detection versus conventional microbiological tests. machine-written summary

46 samples · 46 runs · China · 2025 · 1.02 Gbp / sample

Nucleic acid sequenced
DNA
shotgun metagenomes
Sequencing
Illumina NovaSeq 6000
single-end · 46 runs · extraction and library protocol not reported
Sources
✓Archive record 92○Abstract○Paper text–Supplementary table–External resource–User contribution–Human verified
what each source gave
✓ Archive recordcollection date, country
○ Abstractread; no usable statement
○ Paper textread; no usable statement or table · PMC12685875
– Supplementary tableno supplementary tables available (or none open access)
– External resourcenot covered by the external resources we ingest
– User contributionnothing uploaded yet
– Human verifiednot yet checked by a person · I checked this project — verify it
Study design
Case–control studyread from the paper
people with a condition compared with people without it

Hospitalized patients with suspected infectious disease at one hospital, HIV-positive and HIV-negative, were retrospectively enrolled; tissue mNGS and conventional microbiological tests were performed at the same time and their diagnostic accuracy and consistency compared. machine-written, checked

Groups the source compares: Infectious disease (ID) group (n = 44) · No infectious disease (NID) group (n = 20)

In the data: 46 samples (which samples share a person is not recorded); sampled at: blood / tissue / internal fluids.

Paper and data checks
  • !The paper states 64 participants, but no variable says which samples came from the same person, so the samples cannot be grouped by participant.
  • !The source compares groups, but no sample variable says which group each sample belongs to.
  • iBody site is the project’s single stated site; the samples themselves do not record it.
Which variables the design is drawn from
Design elementFieldComes fromSamples
Personsubject_idnot recorded0 / 46
Group / conditionhealth_conditionnot recorded0 / 46
Body sitebody_site_codethe project's single stated site (98 %); each sample's own record (2 %)46 / 46
Collection datecollection_datearchive attribute ‘collection_date’46 / 46

How this block is assembled

Samples at a glance
  • Blood46 samples · 100 %
1 country
Age
unknown46
Country
China46
Collection year

All 46 dated samples were collected in 2022.

Sequencing depth per sample
0–0.5 Gbp: 6 samples60.5–1 Gbp: 15 samples151–1.5 Gbp: 14 samples141.5–2 Gbp: 6 samples62–2.5 Gbp: 1 sample12.5–3 Gbp: 4 samples40123median 1.02 Gbp per samplemedian 1.02 Gbp
46 samples · linear axis in Gbp · catalog median 3 Gbp (30 % of all catalog samples are shallower than this project's median)
Living conditions and exposure
FieldValueFrom
Recruitment settinghospital inpatientspaper, methods
Community composition

No Sandpiper profile for this project's samples.

No community profile for 46 samples of this project: Meets Sandpiper's selection rule, not on its run list (25); Too small for Sandpiper's selection rule (21). The catalog takes its profiles from Sandpiper and does no profiling of its own.

Field coverage
fieldsamplescoveragearchive recordsupplementary tablepaper textabstract
body_site_code46 100%145
age_category0 0%computed from other fields
country46 100%46
health_condition0 0%
subject_id0 0%
collection_date46 100%46
Papers (1)
  • Diagnostic utility of metagenomic next-generation sequencing for tissue in patients with suspected infectious diseases. 2025 PMID 41376791 PMC12685875 own_data
Details
Archive description

Metagenomic next-generation sequencing (mNGS) was suggested to potentially replace traditional microbiological methods because of its comprehensiveness. However, the diagnostic utility of mNGS for tissue hasnt been fully explored, especially for patient with HIV infection.HIV-positive and negative patients with suspected infectious diseases who performed tissue mNGS and conventional microbiological tests (CMTs) were retrospectively enrolled between October, 2020 and May 2024. The microbial spectrum of tissue mNGS and CMTs was analyzed, and the diagnostic accuracy and consistency of mNGS and CMTs for tissue were compared. The related factors of positive rate of mNGS was analyzed.Of 70 patients with suspected infectious diseases, 44 cases were confirmed with the infectious diseases. Among 44 patients with infectious diseases, aerobic bacteria (36.4%) was the most common detected pathogen, followed by mycobacterium tuberculosis (MTB, 18.2%), non-tuberculous mycobacteria (NTM, 13.6%) and fungus (11.4%). The sensitivity of tissue mNGS (72.7%, 95%CI 56.9%-84.5%) was significantly higher than that that in tissue CMTs (29.5%, 95%CI 17.2%-45.4%) (p<0.001), but the specificity was not statistically significant(P=0.656). mNGS demonstrated higher detection rates than CMTs in the case with single microbial infections (70.0% vs. 30.0% p<0.01). For the case with multiple microbial infections, the detection rates of mNGS and CMTs was 100.0% and 25.5% (p=1.000), respectively. Both positive mNGS and CMTs were observed in 22.7% patients with infectious diseases, and sole positive mNGS and sole positive CMTs were observed in 50.0% and 6.8% patients, respectively. There were no statistically differences in age, gender, HIV infection, PCT levels, neutrophil counts, CD4+ lymphocyte count and antibiotic exposure between mNGS positive and mNGS negative groups (P > 0.05). Tissue mNGS could provide a higher sensitivity, more robust and broader method for pathogen identification by comparison with CMTs. However, CMTs shouldnt be ignored since the low consistency between CMTs and mNGS.

How this project entered the catalog

The registry (archive-only classification) lists it as human blood / tissue / internal fluids shotgun DNA metagenome of age unknown. In the catalog: 46 DNA and 0 RNA shotgun sequencing runs (amplicon and single-cell runs are left out run by run).

  • body site · “next-generation sequencing for tissue in patients with”
  • body site · “of mNGS for tissue hasnt been fully”
Example evidence (one per field and source)
samplefieldvaluewhere it came fromconf.sourcequote
SAMN52963839collection_date2022-11-01archive record0.90sample.attr.collection_date2022-11-01
SAMN52963839countryCNarchive record0.90sample.attr.geo_loc_nameChina: Wuhan

Confidence is a fixed number per source, not a probability — see Fields.

Sequencing

46 runs over 46 samples · mean 1.15 Gbp per run (median 1.02 Gbp, total 53.11 Gbp; 46 runs with a base count) · layout SINGLE 46 · platform ILLUMINA 46 · models Illumina NovaSeq 6000 (46) · 0% of runs with a Sandpiper profile · first public 2025-11-01

Downloads

PRJNA1354999.csv.gz (2.0 KB) · parquet (8.2 KB) — all 46 samples, every field with its source and confidence · PRJNA1354999_determinations.csv.gz (641 B) — 92 evidence rows

Samples (46 · every field this project has values for · hover a cell for its source)
Loading the sample table…