Plasma cfDNA metagenomics in sepsis patients and controls
Shotgun metagenomic sequencing of cell-free DNA from 11 blood plasma specimens from septic patients and healthy controls for pathogen identification. machine-written summary
11 samples · 11 runs · 2019 · 2.6 Mbp / sample
what each source gave
| ✓ Archive record | timepoint |
| ○ Abstract | read; no usable statement |
| – Paper text | no open-access paper text linked |
| – Supplementary table | no supplementary tables available (or none open access) |
| – External resource | not covered by the external resources we ingest |
| – User contribution | nothing uploaded yet |
| – Human verified | not yet checked by a person · I checked this project — verify it |
11 samples (which samples share a person is not recorded); sampled at: blood / tissue / internal fluids.
- !The source describes repeated sampling, but which samples belong to the same person is not recorded, so the time course cannot be drawn.
- iBody site is the project’s single stated site; the samples themselves do not record it.
Which variables the design is drawn from
| Design element | Field | Comes from | Samples |
|---|---|---|---|
| Person | subject_id | not recorded | 0 / 11 |
| Group / condition | health_condition | not recorded | 0 / 11 |
| Body site | body_site_code | the project's single stated site | 11 / 11 |
| Time point | timepoint_label | a naming rule on the sample description | 11 / 11 |
longitudinal — not resolved
- Blood11 samples · 100 %
No Sandpiper profile for this project's samples.
No community profile for 11 samples of this project: Not sequenced on Illumina (11). The catalog takes its profiles from Sandpiper and does no profiling of its own.
| field | samples | coverage | archive record | supplementary table | paper text | abstract |
|---|---|---|---|---|---|---|
| body_site_code | 11 | 100% | 11 | |||
| age_category | 0 | 0% | computed from other fields | |||
| country | 0 | 0% | ||||
| health_condition | 0 | 0% | ||||
| subject_id | 0 | 0% | ||||
| timepoint_label | 11 | 100% | 11 | |||
- Rapid Next-Generation Sequencing–Based Diagnostics of Bacteremia in Septic Patients 2020 PMID 32146977 own_data
- Diagnosing Bacteremia in Real Time Using Next-Generation Sequencing–Based Technology 2020 PMID 31978560 reuse
Archive description
Background: The increasing incidence of bloodstream infections including sepsis is a major challenge in intensive care units worldwide. To improve patient’s outcome, the causative pathogens need to be identified rapidly allowing for an immediate initiation of a targeted antimicrobial therapy. However, current diagnostics for pathogen identification mainly depend on culture- and molecular-based approaches, which are not satisfactory regarding specificity, sensitivity and time to diagnosis. Recently, a highly specific and sensitive diagnostic workflow for bloodstream infections based on unbiased sequence analyses of free circulating DNA (cfDNA) from plasma by next-generation sequencing (NGS) have been developed. However, time to diagnosis still took approximately 24-36 hours.Methods: In the present work we established a complete diagnostic workflow for real-time high-throughput sequencing based on nanopore sequencing. Accordingly, we optimized wetlab protocols and bioinformatic procedures in order to allow a more rapid identification of pathogens without losing specificity and sensitivity. This workflow was then applied to the analyses of samples from eight septic patients and three healthy controls and compared to standard NGS results.Results: We initially optimized standard library preparation protocols for short fragments with low input amounts and could achieve a 3.5-fold increase in sequencing throughput. With tailored bioinformatic workflows, all eight septic patient samples were found to be positive for the relevant pathogens. When considering time to diagnosis, depending on the microbial burden for seven of the eight samples first pathogens were already identified within minutes to one hour after start of sequencing. Moreover, a statistical extrapolation of real-time sequencing performance on a cohort with 239 septic patient samples validated by standard NGS diagnostic workflows revealed that more than 90 % of the pathogen hits would have also been detected with the optimized MinION workflow despite its currently still limited throughput and sequencing quality.Conclusions: Reliable identification of pathogens based on cfDNA sequencing using optimized workflows and real-time nanopore-based sequencing can be accomplished within 5-6 hours after blood draw. Therefore this approach might provide therapy-relevant results in a clinically critical timeframe.
How this project entered the catalog
The registry (archive-only classification) lists it as human blood / tissue / internal fluids shotgun DNA metagenome of age unknown. In the catalog: 11 DNA and 0 RNA shotgun sequencing runs (amplicon and single-cell runs are left out run by run).
- body site · “DNA (cfDNA) from plasma by next-generation sequencing”
Example evidence (one per field and source)
| sample | field | value | where it came from | conf. | source | quote |
|---|---|---|---|---|---|---|
| SAMEA4852951 | timepoint_label | patient 10 time point T0 | archive record | 0.80 | sample.name_rule:DESCRIPTION | DESCRIPTION = S10_T0 |
Confidence is a fixed number per source, not a probability — see Fields.
Sequencing
11 runs over 11 samples · mean 2.7 Mbp per run (median 2.6 Mbp, total 29.9 Mbp; 11 runs with a base count) · layout SINGLE 11 · platform OXFORD_NANOPORE 11 · models MinION (11) · 0% of runs with a Sandpiper profile · first public 2019-08-15
Downloads
PRJEB28340.csv.gz (1.1 KB) · parquet (6.5 KB) — all 11 samples, every field with its source and confidence · PRJEB28340_determinations.csv.gz (605 B) — 11 evidence rows